Lumimark - Safety Traffic Marking System

The Need

Masters Builders, Inc. developed Lumimark HW 100 White and Yellow, polymer-modified, cementitious safety traffic marking products.

It's designed for use in edge and center line striping on concrete pavement for both mainline and secondary roads, and all striping needs on runways, taxiways and aprons at airports. This product can be recommended for:

  • New concrete pavement

  • Retrofit concrete pavement

  • Airport runways, taxiways and aprons

  • Where reflective curbs and light standards are required

  • Normal to hot weather conditions (60 to 110 F)

The Technology

This technology helped the Department avoid a costly bridge replacement project by rehabilitating a steel truss bridge using lightweight composites. Reducing dead load on the bridge by 265 tons, the application of this technology doubled the load ratings to a level higher than the original design and allowed weight restrictions to be removed, while saving $1.4 million in the process. This was the first time this type of rehabilitation was accomplished in the United States.

The Lumimark pavement marking system is integrated into the concrete pavement rather than applied to the surface. Installed into a groove ¼ inch deep in the concrete pavement, Lumimark becomes part of the pavement, having the strength and durability of concrete. Glass beads and pigments are incorporated throughout the polymer-modified cementitious matrix of the Lumimark material, giving it long-lasting visibility. It can be used on both highways and airport runways. Performance Data - a is following as:

Working Time

Approx. 30 minutes at 70 F

Compressive Strength
(ASTM C 109, modified)

 

    1 day 

  2000 psi (13.8 MPa)

    7 day 

  4000 psi (27.6 MRs)

  28 day 

  5000 psi (34.5 MRa)

Flexural Strength (AS TM C 348, modified)

 

    1 day 

  500 psi (3.4 MPa)

    7 day

  600 psi (4.1 MPa)

  28 day 

  700 psi (4.8 MPa) 

Splitting Tensile Strength 
(AS TM C 496, modified)

 

    1 day 

  250 psi (1.7 MRs) 

    7 day 

  350 psi (2.4 MPa)

  28 day 

  450 psi (3.1 MPa)

Length Change,%- (AS TM C 157, modified)

 

  28 day

  0.08%

Pull-Oft Bond (ASTM C 4541)

 

    1 day

  100 psi (0.7 MPa)

    7 day

  150 psi (1.0 MPa)

  28 day

  200 psi (l.4 MPa)

Retro-reflectivity (ASTM 04061)

 

   86.0 Entrance Angle

  Yellow - 250 mcd/m2/Lx

   0.2 Observation Angle

  White - 350 mcd/m2/Lx

Freeze-Thaw Resistance 
(AS TM C 666, A) 300 cycle
s

Relative Durability Factor (RDF)

   No.1 Sealed, ¼ in. (6 mm) composite - b

  90%

   No.2 Plain, Solid Beam

  95%

  1. The data shown is representative of laboratory tests of 2 day moist cured samples. Reasonable variations from results shown may be experienced as a result of atmospheric and jobsite conditions. Mix entire bag of LUMIMARK HW 100 when preparing compressive strength specimens.

  2. Composite beam prepared by overlaying ¼  in (6 mm) of product on hardened concrete.

Benefits

  • Retro-reflectivity equal to or greater than that of other marking systems

  • Highly durable and cost-effective compared to other high-performance marking systems

  • Surface and integral glass beads for long lasting retro-reflectivity

  • Compressive strength equal or greater to that of typical concrete pavement

  • Thermally compatible with concrete pavement

  • Approximately 30 minutes working time at 70F (21C)

  • Excellent bond to base concrete

Status

Founded in 1909, Master Builders, Inc. has focused on the development, manufacturing and marketing of construction chemicals committed to improving concrete. The Civil Engineering Research Foundation (CERF) announced Lumimark - Safety Traffic Marking System as one of four finalists for the 2000 CERF Charles Pankow Award for Innovation.

Barriers

 Longer installation duration and more labor power for installation are required compared to traditional line painting method.

Points of Contact

  1. Mr. Phil Zivich, Master Builders, Inc. 23700 Chagrin Blvd, Beachwood, OH 44122. Tel: (216) 831-5500, Fax: (216) 831-6910. Email: pzivich@mbt.com

  2. Mr. Phil Dyer, Lumimark Systems, Inc., 7135 South Tuscon way, Suite 100, P.O.Box 4356, Englewood, CO, 80155. Tel: (303) 790-9100, Fax: (303) 790-4380 Email: pdyer@ihcinc.net

  3. Master Builders Inc. United States. 23700 Chagrin Boulevard, Cleveland, Ohio 44122-5554. Tel: (800) MBT-9990, Fax: (216) 831-6910

References

  1. Master Builders Technologies <http://www.masterbuilders.com/>

  2. CERF Charles Pankow Award for Innovation <http://www.cerf.org/about/press/7_21_00A.htm>

Disclaimer Statement

Neither the Construction Industry Institute nor Purdue University in any way endorses this technology or represents that the information presented can be relied upon without further investigation.

SL46 

Division of Construction Engineering and Management
Purdue University, 550 Stadium Mall Drive
West Lafayette, IN 47907 - 1294
Ph: +1 765 494 2344 Fax: +1 765 494 0644
| New Additions | Civil | Mechanical | Internet-based | Electrical | Other |
|
About This Site | Subscribe | Best Links | Suggest a Technology |
|
Print This Page | Search | Link to Us | Contact Us | Help | Home |
Last Modified: Tuesday, 29-Jul-08 15:16:17 EDT